Flexible Rubber Insulation Electric Welding Cable APPLICATIONS:
For secondary side connection of power sources for hand or automatic metal-arc welding where required hard usage and heavy duty portable supply in dry,wet and oil environment.Suitable for connection of motors,generators,transformers,etc.where flexible connections are required.

RATED VOLTAGE:
For secondary voltage typical of welding equipment and for fixed protected
laying up to 600V.Maximum permissible conductor temperature 90'C


Flexible Rubber Insulation Electric Welding Cable FEATURES:
High strength tear-resistant jacket
Excellent resistance to abrasion and impact
Superior flexibility,even at cold temperature to -50'C
Flame resistant
Special stranded conductor for added flexibility and handling


Flexible Rubber Insulation Electric Welding Cable SPECIFICATION:
Annealed bare copper high flexible conductors
Single layer in PVC materials
Double insulation PVC available on special request
ROHS,PAHS,REACH available upon request


SEPARATORS:
Various,such as paper,polyester film,or polyester

STANDARD DELIVERY LENGTHS:
Up to 35mm2 in coils of 100m,50 to 120 mm2 in coils of 50m.
Other lengths available on special request
Longer delivery lengths on drums upon request
  SIZE NO STRANDS STRAND SIZE SHEATH THICKNESS
 10mm2 320pcs  0.20mm 2.0mm
16mm2 513pcs  0.20mm 2.0mm
25mm2 798pcs  0.20mm 2.0mm
35mm2 1115pcs  0.20mm 2.0mm
50mm2 1596pcs  0.20mm 2.2mm
70mm2 2214pcs  0.20mm 2.4mm
95mm2 2997pcs  0.20mm 2.6mm
120mm2 612pcs  0.50mm 2.8mm

Previous Product: 35MM2 Rubber Welding Cable

 

Rubber insulated 70mm2 welding cable

Rubber insulated 70mm2 welding cable

70mm2 Welding cable

The welding cable can be produced according to the standard IEC 81(YH) & IEC82 (YHF)


Rubber insulated 70mm2 welding cable/Welding cable:
Rubber insulated 70mm2 welding cable - Standard
the welding cable can be produced according to the standard GB5013.6-1997 and 245 IEC 81.

Rubber insulated 70mm2 welding cable -Specific Property for Using
(1).The cable can be used in the connectors of electric weld and pliers of the electrical welding whose toward

      earth voltage of the low voltage is not more than AC 200 V and the pulsant DC peak value is 400V.
(2).The long-time permissible working temperature of cable is not more than 65.

Rubber insulated 70mm2 welding cable -Name and IEC Standard
   (1).Rubber Sheathed Welding Cable 245 IEC 81
   (2).Rubber Sheathed Welding Cable 245 IEC 82,which is made of chloroperene or the composite stretchy materials.

4.The general data of the cable 245 IEC 81 and 245 IEC 82
70mm2 welding cable,flexible rubber cable

Nominal Cross-sectional Area of Conductor (mm2)
Diameter of single wire of conductor
Total thickness of covering Specified value (mm)
Thickness of Sheath of composite covering Specified value
Average Outer Diameter
Max. conductor resistance at 20
Approx. weight (kg/km)
Lower Limited
Higher Limited
10
0.21
1.8
1.2
7.5
9.7
1.91
142.00
16
0.21
2.0
1.3
8.8
11.0
1.19
214.00
25
0.21
2.0
1.3
10.1
12.7
0.780
310.00
35
0.21
2.0
1.3
11.4
14.2
0.552
410.00
50
0.21
2.2
1.5
13.2
16.5
0.390
573.00
70
0.21
2.4
1.6
15.3
19.2
0.276
786.00
95
0.21
2.6
1.7
17.1
21.4
0.204
1041.00
120
0.21
2.8
1.8
19.0
24.0
0.161
1303.00
150
0.21
3.0
1.9
21.0
27.0
0.129
1615.00
185
0.21
3.2
2.0
22.0
29.0
0.106
1974.00

 

Rubber Insulated Flexible Cable

Rubber Insulated Flexible Cable

Rubber Insulated Flexible Cable


Rubber Insulated Multi Core Flexible Cable 4mm  6mm  10mm 

Rubber Insulated Flexible Cable Standard
the welding cable can be produced according to the standard 245 IEC 81,ICEA S-75-381

Rubber insulated cable

Rubber Insulated Flexible Cable Specific Property for Using
(1).The cable can be used in the connectors of electric weld and pliers of the electrical welding whose toward earth voltage of the low voltage is not more than AC 200 V and the pulsant DC peak value is 400V
(2).The long-time permissible working temperature of cable is not more than 65.

Rubber Insulated Flexible Cable Name and IEC Standard
(1).Rubber Sheathed Welding Cable 245 IEC 81
(2).Rubber Sheathed Welding Cable 245 IEC 82,which is made of chloroperene or the composite stretchy materials.

Rubber Insulated Flexible Cable Conductor Materials:
Copper, Tinned Copper or CCA
Jacket:
Rubber or PVC
Rubber Insulated Flexible Cable Applications:

Rubber welding cable can be fixedly laid in various environments such as indoor/outdoor, aerial, cable conduit or tunnel for power transmission and distribution line project, with rated A/C Uo/U being 450/750V or below. It widely used in outside small electric devices, agriculture electrification, construction lifts and gantries. And it is suitable for welder connection which is operates under Uo/U 220V.


Rubber Insulated Cable Parameter
Voltage Uo/U 300/500V 450/750V
Material: Copper conductor, rubber jacket, rubber/PVC insulation
Permitted working temperature of cable conductor should not be over 65°C for long service period.
When there is any short-circuit occurs (lasting time less than 5s), the maximum temperature of the cable will not exceed 160°C 5. Perfect bending properties, installed and maintained easily and conveniently.
More flexible, good wear-resisting and resistant to water, oil.

Specification
Type: YQ YQW, YZ YZW, YC YCW, JHS JHSB, YH YHF.
Standard: IEC CCC
Specification: 1-5 cores 3+1 4+1 1.5mm2-240mm2 etc.
Length: 500M 1000M
No minal Section
Area(mm2)

Copper Wire
No./Dia.(mm)

Insulated Sheath
Thickness(mm)

Average of the Max
Outer Dia(mm)

Conductor Resistance
at 20(≤Ω/km)

Weight
(kg/km)

10
322/0.20
1.8
9.7
1.91
151.6
16
513/0.20
2.0
11.5
1.61
224.0
25
798/0.20
2.0
13.0
0.758
326.0
35
1121/0.20
2.0
14.5
0.536
430.0
50
1596/0.20
2.2
17.0
0.379
600.0
70
2214/0.20
2.4
19.5
0.268
818.1
95
2297/0.20
2.6
22.0
0.198
1082.7


 

Multi-core rubber sheathed flexible cable

Multi-core rubber sheathed flexible cable

1. highly resistant to electric strength
2 .Long time allow working temperature of wire core is not more than 65 degrees C

Multi-core power rubber sheathed flexible cable(PVC sheath)
flexible cable/ power cable/ PVC cable

Multi-core rubber sheathed flexible cable Application scope

The rubber insulated rubber sheathed power cable with rated voltage at is  0.6/1kV will be applied to power, lighting and control system on shipboard and off shore platform, and it aslo available to metallurgical industry, chemical works, power plant and mining indudtry ect.

Multi-core rubber sheathed flexible cable Usage
Submersible Pump Cable used in the water below (30-50metres) long-term, waterproof anti-corrosion feature, high quality and safe.
Rubber Sheath Flexible Cable YC IEC60245-66YCW
Detailed Product Description
Rubber Sheath Flexible Cabl
Rubber sheath cable is suitable for rated AC vo1tage 450/750V or below domestic applies, power-operated tools and various portable electric Equipments
Multi-core rubber sheathed flexible cable Working temperature
    1)  YZ model rated voltage Uo/U is 300/500V, YC model is 450/750V
    2)  Long time allow working temperature of wire core is not more than 650C
    3)  W model cable has the property of durability and suitable for outdoor touching   of  greasy dirt
    4)  ZR model cable has the property of fire-resistance
Construction of cable

    1.tinner copper conductive cores
    2.rubber  insulated
    3.wrapping
    4.PVC/XLPE/PO inner sheath
    5.metal wire braided
    6.PVC/XLPE/PO outer sheath

Multi-core rubber sheathed flexible cable

Model name and usage
Model
Name
Rated Voltage(V)
Section Area(mm2)
No. of Cores
Usage
YQ,YQW
Light model rubber sheath flexible cable
300/500
0.3--0.5
2,3
Used for light portable electric equipment and tools
IEC60245-53YZ
Middle model rubber sheath flexible cable
300/500
0.75--6
2,3,4,5
Used for various portable electric equipment and tools
IEC60245-57YZW
YC
Heavy model rubber sheath flexible cable
450/750
1.5--400
1
Used for various portable electric equipment which can bear large mechanical force effect
1.5--95
2
1.5--150
3
IEC60245-66YCW
1.5--150
4
2.5150
+
1.5--50
3+1
1.5--25
 
 

 

Rubber Insulated Coal Mining Cable

Rubber Insulated Coal Mining Cable

Rubber Insulated Coal Mining Cable


rubber insulated cable,
flexible rubber cable,
power cable,

rubber insulate coal mining cable picture:
rubber insulate coal mining cable

Standard: VDE0282, Bs6360, IEC53/57/66

Rated Voltage: 300/500V 450/750V
Cross-section Area:  0.5mm2 - 400mm2
Temperature: 60/90/105 celsius degree
H05RR-N, H07RR-F & H07RN-F are applicable as well.

Rubber Insulated Coal Mining Cable detailed information:
1. Cable working temperature should not exceed 65 degree
2. Cable have a certain extent of temperature resistance and oild resistance, fit to work outdoor and smeary enviroment
3. Reach standard GB/T18380.1-2001 vertical flame test
4. When cable working in temperature 20 degree ,the insulation between
Conductors above 50M .KM
Applicable scope: Rated voltage 300/750V or below, applied in electric
Appliance ,elctromotive tools and equipment


Rubber Insulated Coal Mining Cable

Implemented standard:
1. For the non-spread combustion cable, implement GB12972 
2. For the flame-retardant cable, implement MT818
3. For the special mining cable (with bigger cross-section and higher voltage), implement the enterprise standard.
Type and Name: 
Type
Description
Application
MC-0.38/0.66
Rubber flexible cable for excavator
As the power connection used 
in the excavator or similar equipment 
with rated voltage 0.38/0.66kV
MCP-0.38/0.66
Shielded, rubber-sheathed flexible
 cable for excavator
As the power connection used 
in the excavator or similar equipment 
with rated voltage 0.38/0.66kV
MCP-0.66/1.14
Shielded, rubber flexible cable for excavator
As the power connection used 
in the excavator or similar 
equipment with rated voltage 0.38/0.66kV
MCPJB-0.66/1.14
Shielded ,monitoring and braiding 
reinforced type, rubber flexible cable for excavator
As the power connection used 
in the excavator or similar 
equipment with rated voltage 0.66/1.14kV,
it can be dragged directly
MCPJR-0.66/1.14
Shielded ,monitoring and braiding reinforced type, 
rubber flexible cable for excavator
As the power connection used 
in the excavator or similar 
equipment with rated voltage 0.66/1.14kV,
it must be used in the protective chain panel
MCPT-0.66/1.14
Metallic shielded rubber flexible cable for excavator
As the power connection used 
in the excavator or similar equipment 
with rated voltage 0.66/1.14kV
MCP-1.9/3.3
Shielded rubber flexible cable for excavator
As the power connection used 
in the excavator or similar equipment 
with rated voltage 1.9/3.3kV
MCPT-1.9/3.3
Metallic shielded rubber flexible cable for excavator
As the power connection used 
in the excavator or similar equipment 
with rated voltage 1.9/3.3kV
MCPTJ-1.9/3.3
Metallic shielded, monitoring type, 
rubber flexible cable for excavator
As the power connection used 
in the excavator or similar equipment 
with rated voltage 1.9/3.3kV
MY-0.38/0.66
Movable rubber flexible cable for mining
As the power connection used 
in the mining machine with 
rated voltage 1.9/3.3kV
MYP-0.38/0.66
Movable shield rubber flexible cable for mining
As the power connection used
in the mining machine 
with rated voltage 0.38/0.66kV
MYP-0.66/1.14
Movable shield rubber flexible cable for mining
As the power connection used 
in the mining machine with 
rated voltage 0.66/1.14kV
MYPJ-3.6/6
Monitoring movable shield rubber
 flexible cable for mining
As the power connection used 
in the mining transformer and 
similar equipment with rated 
voltage3.6/6kV
MYPTJ-3.6/6
Metallic shielded monitoring type 
movable rubber flexible cable
As the power connection used 
in the mining transformer and 
similar equipment with rated 
voltage3.6/6kV
MYP-3.6/6
Movable shield rubber flexible cable for mining
Mining equipment with rated voltage 
3.6/6kV the min. environment 
temperature is-20℃
MYPT-3.6/6
Movable metallic shield rubber 
flexible cable for mining
Mining equipment with rated 
voltage 3.6/6kV the min. 
environment temperature is-20℃
MYPD-3.6/6
Movable shield rubber flexible cable for mining
Mining equipment with rated 
voltage 3.6/6kV the min. 
environment temperature is-40℃
MYPTD-3.6/6
Movable metallic shield rubber 
flexible cable for mining
Mining equipment with rated 
voltage 3.6/6kV the min. 
environment temperature is-40℃
MZ-0.3/0.5
Driller cable for mining
As the power connection 
of driller with rated voltage 0.3/0.5kV
MZP-0.3/0.5
Driller shielded cable for mining
As the power connection of 
driller with rated voltage 0.3/0.5kV
MYQ-0.3/0.5
Movable light-type rubber 
flexible cable for mining
Lighting in the mine, as the 
power connection of the interlock 
and control signals used in the transport 
machine and equipment
Rubber Insulated Coal Mining Cable
1.Feature:
 1) The allowed operating temperature of the core is 65°C when U0/U is 
    0.66/1.14kV and below, 85°C when U0/U is 3.6/6kV
 2) Min. bending radius is 6 times the size of cable diameter
 3) The yellow sheath cable should not be exposed in the sun for long time
 4).Coal Mining Machine Cable:The cables are suitable for coal mining machine and similar equipment as power connecting cable.

3.Constructional dimension and technical parameter
Cores No. ×
Cross-sectional
area mm2
 Approx. overall
diameter
mm
Phase Core Insulation Resistance at 20°C
≥MΩ•km
kg/km
Approx. weight
kg/km
3×16+1×16
58.5-63.5
610
4648
3×25+3×10
56.2-61.2
550
5168
3×35+3×10
59.2-64.2
500
5861
3×50+3×16
63.1-68.1
440
7166
3×70+3×16
69.5-74.5
390
8771
3×95+3×16
74.0-79.0
350
10126
3×120+3×25
79.0-84.0
330
11827
3×150+3×25
83.3-88.3
300
13554
3×185+3×35
87.6-93.6
280

rubber insulated cable,flexible rubber cable,rubber welding cable

 

Tinned copper rubber insulated cable

Tinned copper rubber insulated cable

Tinned copper rubber insulated cable


rubber welding cable,
Tinned copper flexible cable,


copper rubber welding cable
Conductor : Bare annealed copper flexible conductor. Tinned Cooper
Insulation: Nitrile-Butadiene-PVC Copolymer (TP-90,met RoHS) or Rubber Material
Sheath: Nitrile-Butadiene-PVC Copolymer (TP-90,met RoHS) or Rubber Material
  • Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
  • SQ MM sizes (European style) 10 sq mm to 240 sq mm
  • AWG sizes (North American style) 6 Awg to 500 MCM
  • With sequential foot / meter marking
  • Wide temperature range: -55°C to 105°C
  
What Is Welding Cable?                                                             
Tinned copper rubber insulated cable is used to power the secondary circuit of electric welding generators,
the circuit that controls the electrode that emits the charge used to weld.
This cable is made from flexible copper wire surrounded by a protective covering
that is resistant to flame, heat, oil and abrasions, among other things.
While welding cable is not meant to be part of any other system,
It has a history of being used for public lighting arrangements.

Tinned copper rubber insulated cable Applications                                                                                     
Designed for the secondary (high current) connection to automatic
welding electrodes. It is suitable for flexible use under rugged conditions,
conveyor systems, in machine tool and automatically operated line and welding machines.
Power
Earthing return leads, power feeds to electrolytic plating process,
Busbar connection, transformers, generators, aircraft servicing equipments etc.
Tinned copper wire flexible rubber insulated cable Instruction
Tinned copper wire flexible rubber insulated cable
Conductor
the conductor is tinned copper wires, which have very good conductive property, and  resistance to oxidation.
Insulation
the insulated material adopts native rubber with good insulation performance. And it is enough flexible.
Outer jacket
the sheathed material is butyronitrile, which is oil resistant, acid and alkali resistant.

Cores*Conductor Nominal Section (mm²)
 
Conductive Core No. / Dia.(mm)
Thickness of Insulation (mm)
Thickness of Sheath (mm)
Average Outer Diameter (mm)
Resistance at 20 degree ≤(Ω/km)
Reference Weight (kg/km)
Min
Max
1×1.5
30/0.25
0.8
1.4
5.8
7.2
13.3
52.1
1×2.5
49/0.25
0.9
1.4
6.4
8
7.98
69.5
1×4
56/0.30
1
1.5
7.4
9
4.95
96.6
1×6
84/0.30
1
1.6
8
11
3.3
132.8
1×10
84/0.40
1.2
1.8
9.8
12.5
1.91
211.9
1×16
126/0.40
1.2
1.9
11
14.5
1.21
283
1×25
196/0.40
1.4
2
12.5
16.5
0.78
410
1×35
276/0.40
1.4
2.2
14
18.5
0.554
545
1×50
396/0.40
1.6
2.4
16.5
21
0.386
734
1×70
360/0.50
1.6
2.6
18.5
23.5
0.272
1010
1×95
475/0.50
1.8
2.8
21
26
0.206
1291
1×120
608/0.50
1.8
3
23.5
28.5
0.161
1558
1×150
756/0.50
2
3.2
26
31.5
0.129
1937
1×185
125/0.50
2.2
3.4
27
34.5
0.106
2330
1×240
1221/0.50
2.4
3.5
30.5
38
0.0801
2989
1×300
1525/0.50
2.6
3.6
33.5
41.5
0.0641
3608
2×1.5
30/0.25
0.8
1.5
9
11.5
13.3
122
2×2.5
49/0.25
0.9
1.7
10.5
13.5
7.98
179
2×4
56/0.30
1
1.8
12
15
4.95
249
2×6
84/0.30
1
2
13.5
18.5
3.3
352
2×10
84/0.40
1.2
3.1
18.5
24
1.91
636
2×16
126/0.40
1.2
3.3
21
27.5
1.21
883
2×25
196/0.40
1.4
3.6
25
31.5
0.78
1276
2×35
276/0.40
1.4
3.9
27.5
35.5
0.554
1695
2×50
396/0.40
1.6
4.3
32
41
0.386
2331
2×70
360/0.50
1.6
4.6
36
46
0.272
3078
2×95
475/0.50
1.8
5
40.5
50.5
0.206
3893
3×1.5
30/0.25
0.8
1.6
9.6
12.5
13.3
150
3×2.5
49/0.25
0.9
1.8
11.5
14.5
7.98
220
3×4
56/0.30
1
1.9
13
16
4.95
308
3×6
84/0.30
1
2.1
14.5
20
3.3
436
3×10
84/0.40
1.2
3.3
20
25.5
1.91
790
3×16
126/0.40
1.2
3.5
22.5
29.5
1.21
1051
3×25
196/0.40
1.4
3.8
26.5
34
0.78
1527
3×35
276/0.40
1.4
4.1
29.5
38
0.554
2029
3×50
396/0.40
1.6
4.5
34.5
43.5
0.386
2805
3×70
360/0.50
1.6
4.8
39
49.5
0.272
3573
3×95
475/0.50
1.8
5.3
44
54
0.206
4734
3×120
608/0.50
1.8
5.6
48
59
0.161
5784
3×150
756/0.50
2
6
53
66.5
0.129
7126